  Datasheet File OCR Text:
  1 description typical applications ordering information technical data single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (m-type tm cbe to en 60934). designed for plug-in mounting with e-t-a sockets 17-p10-si, 23-p10-si, 63-p10-si; or panel mounting using e-t-a clips. featuring an unprotected shunt tap terminal and optional auxiliary contacts. type 3900 offers lower internal resistance values and is fitted as standard with auxiliary contacts and an intermediate reset position in which all contacts are isolated. approved to cbe standard en 60934 (iec 60934). process control systems, instrumentation, communications systems, rail vehicles. 3600 3900 standard type low-resistance type for further details please see chapter: technical information voltage rating ac 240 v, 50/60 hz; dc 65 v (ul: ac 250 v; dc 65 v) current rating range 3600: 0.05...16 a 3900: 0.05...10 a auxiliary circuit 1 a, ac 240 v / dc 65 v typical life 5,000 operations at 1 x i n , inductive 5,000 operations at 2 x i n , resistive ambient temperature -30...+60 c (-22...+140 f) insulation co-ordination rated impulse pollution (iec 60664 and 60664 a) withstand voltage degree 2.5 kv 2 reinforced insulation in operating area dielectric strength (iec 60664 and 60664a) test voltage operating area ac 3,000 v main/aux. circuit ac 1,500 v aux. circuit 4-5/6-7 ac 840 v insulation resistance >100 m (dc 500 v) interrupting capacity i cn 3600 3900 0.05...0.8 a 0.05...0.2 a self-limiting 1...2 a 0.3...2 a 200 a 2.5...16 a 2.5...10 a 400 a interrupting capacity i n u n (ul 1077) 0.05...16 a ac 250 v 1,000 a type 3600: 0.05...16 a dc 80 v 1,000 a degree of protection operating area ip40 (iec 60529/din 40050) terminal area ip00 vibration 5 g (57-500 hz), 0.38 mm (10-57 hz) to iec 60068-2-6, test fc 10 frequency cycles/axis shock 25 g (11 ms) to iec 60068-2-27, test ea corrosion 96 hours at 5 % salt mist to iec 60068-2-11, test ka humidity 240 hours at 95 % rh to iec 60068-2-78, test cab mass approx. 45 g type no. 3600 standard version with shunt tap terminal -3 3900 low-resistance version terminal design p10 blade terminals 6.3-0.8 (qc .250) auxiliary contacts (3900: intermediate position as standard) si with blade terminals 6.3-08,one each no/nc, current ratings 0.05...16 a (type 3600) 0.05...10 a (type 3900) 3600 - p10 - si - 10 a ordering example the exact part number required can be built up from the table of choices shown above. ordering references for optional features should be omitted if not required. standard current ratings and typical internal resistance values current ratings (a) internal resistance () current ratings (a) internal resistance () 3600 3900 3600 3900 0.05 447 211 3 0.19 0.054 0.1 131 48 4 0.090 0.035 0.2 40 12.4 5 0.061 0.025 0.3 19.3 5.4 6 0.041 0.02 0.4 10.4 3.1 7 0.034 0.02 0.5 7.1 2.0 8 0.02 0.02 0.6 4.3 1.32 10 0.02 0.02 0.8 2.5 0.76 12 0.02 1 1.67 0.49 14 0.02 1.5 0.61 0.21 15 0.02 2 0.38 0.101 16 0.02 2.5 0.24 0.078 preferred types standard current ratings (a) 0.5 1 2 4 8 10 16 3600-p10-si- x x x x x x x 3900-p10-si- x x x x preferred types thermal-magnetic circuit breakers 3600/3900 www.e-t-a.de 1646 1
2 dimensions internal connection diagrams 14 6 1 1 4 ?11.5 ?6.5 ?4 ?8.5 6.8 6 x 6.8 = 40.8 10 19 51 2 5 on 11 off blade terminals din 46244-a6.3-0.8 (qc .250) 8.5 50 20 13 43 11.5 current rating in a 2 14 63 75 2 .157 .079 .256 .453 .335 .433 .197 2.01 .394 .268 6 x .268 = 1.61 .748 .787 1.69 .512 .335 1.97 .453 -p10-si 3 (from i n =8 a) 3 (from i n =8 a) 7 6 line 1 2 line 1 3 2 5 4 i > 3 i > with shunt terminal (standard) and auxiliary contacts (-si) only 3600 12 3 terminal design -p10 installation drawing typical time/current characteristics +60 c +140 f +23 c +73.4 f -30 c -22 f ? times rated current 12 46 81 02 04 0 ? times rated current 10000 1000 100 10 1 0.1 0.01 0.001 60 80 100 trip time in seconds 12 46 81 02 04 0 10000 1000 100 10 1 0.1 0.01 0.001 60 80 100 trip time in seconds trip time in seconds 12 46 81 02 04 0 ? times rated current 10000 1000 100 10 1 0. 1 0.01 0.001 60 80 100 3900 0.05?10 a dc 2) 3600 8?16 a ac 1) 3600 0.05?7 a ac 1) 1) magnetic tripping currents are increased by 20 % on dc supplies. 2) magnetic tripping currents are decreased by 20 % on ac supplies. this is a metric design and millimeter dimensions take precedence ( mm ) inch the time/current characteristic curve depends on the ambient temperature prevailing. in order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. see also section technical information. ambient temp. f c -22 -30 -4 -20 +14 -10 +32 0 +73.4 +23 +104 +40 +122 +50 +140 +60 derating factor 0.76 0.79 0.83 0.88 1 1.08 1.16 1.24 thermal-magnetic circuit breakers 3600/3900 www.e-t-a.de 1646 1
3 accessories blade terminal din 46244 part 2 c profile (2xa2.8-0.8) (qc 2x.110) depth 10 mm (.394 in.) adapter x20040901 symmetrical rail en 50022-35x7.5 polarization recess g-profile en 50035-g32 8.5 25.8 6.5 80 33.3 10 5 1.4 12.5 41.3 45.8 retaining clip 10 2.8 -p70 1 11 23 2(k) 12 24 2(i) 1 11 23 2(k) 12 24 2(i) 1.80 1. 63 .335 .256 1.02 3.15 1.31 .055 . 197 .492 .394 . 39 4 .110 depth 10 mm (.394 in.) adapter x20040901 symmetrical rail en 50022-35x7.5 polarized blade terminal din 46244-a6.3-0.8 (qc .250) polarization r ecess g-profile en 50035-g32 slot fitting labels from phoenix, weidmller 8.5 25. 8 6.5 80 33.3 10 5 1.4 12.5 41. 3 45.8 retaining clip 10 6.3 -p10 1 11 23 2(k) 12 24 2(i) 1 11 23 2(k) 12 24 2(i) 1.80 1. 63 .335 .256 1.02 3.15 1.31 .055 . 19 7 .492 .394 .394 .248 sockets 23-p10-si 63-p10-si (up to 16 a max. load) retaining clip y 300 581 03 to special order. sockets 17-p10-si (up to 16 a max. load) 17-p10-si-20025 mounted with adapter retaining clip y 300 581 11 to special order. sockets 17-p70-si (up to 16 a max. load) 17-p70-si-20025 mounted with adapter retaining clip y 300 581 11 to special order. 6 x 6.8 = 40.8 6 x .268 = 1.61 retaining clip 22.2 21 10 2 max. 30 6 3.5 6.8 7.4 4.4 64 50 57.4 25 12.5 4.4 7.4 12.5 6.25 64 50 75 12.5 polarized blade terminals din 46244-a6.3-0.8 (qc .250) po larized recess .173 .291 2.52 1.97 2.26 .492 .984 .291 .173 .394 .827 .874 .079 .236 max. 1.18 2.52 .492 1.97 2.95 50 1 .97 2 .26 57.4 .268 .1 38 .492 .246 slot fitting labels from phoenix, weidmller 63 en 50022-35x7,5 en 50035-g32 115 47 42,5 51 11,5 57 6 25 25 max. 38 11 14 17 plus 11 14 2.2 12.1 12.2 1.2 line 1.1 line 2.1 slot for fitting labels from phoenix, weidmller, wieland slot for busbar module right-side terminal block left-side terminal block symmetrical rail g-profile test socket module 17plus for technical data see section power distribution systems approvals authority standard voltage ratings current ratings 3600: vde iec/en 60934 ac 240 v dc 65 v 0.05...16 a 0.05...16 a ul c22.2 no. 235 ac 250 v dc 80 v 0.05...16 a 0.05...16 a csa ul 1077 ac 250 v dc 80 v 0.05...16 a 0.05...16 a 3900: vde iec/en 60934 ac 240 v dc 65 v 0.05...10 a 0.05...10 a power-d-box with sockets pre-wired 19bgt2 2u for 18, 24 or 30 circuits. for technical data see product group power distribution systems. thermal-magnetic circuit breakers 3600/3900 www.e-t-a.de 1646 1 thermal-magnetic circuit breakers 3600/3900
4 accessories 1 1 0.5 2 7.5 12.5 7.3 8 m4 8.5 60.4 50 16.5 20 2 .075 .039 .295 .079 .020 .079 .335 .287 .315 .492 .650 .787 2.38 1.97 100 quick-connect tabs 6.3 (.250) din 46247 tinned brass, insulated connector bus links -p10 x 210 588 01/ 1.5 mm 2 (awg 16), brown up to 13 a max. load x 210 588 02/ 2.5 mm 2 (awg 14), black up to 20 a max. load x 210 588 03/ 2.5 mm 2 (awg 14), red up to 20 a max. load x 210 588 04/ 2.5 mm 2 (awg 14), blue up to 20 a max. load ~2.76 ~70 9 5.4 125 17 .669 .213 .354 4.92 2 cylinder head screw washer m4x4 iso1207 nickel plated a 4.3 din 125 nickel plated female connector phoenix terminal akg 35 max.cross section 35 mm 2 (awg 2) m4 10 12.8 7 154.8 pressure-relief joint (1.1 mm (.043 in.) thick constriction) cu rail, tin-plated .394 .079 .504 .276 6.09 extraction tool y 301 398 02 bus bar (10-way) (supplied as a complete package) for socket 17 (for max. 100 a continuous load ) x 211 157 01 with terminal x 211 157 02 without terminal (more positions available on request) insulate sleeving for bus bar y 303 824 01 mounting clip y 300 504 02 (2 pcs needed per unit) installation drawing with mounting clips y 300 504 02 56 46 2.21 1.81 this is a metric design and millimeter dimensions take precedence ( mm ) inch all dimensions without tolerances are for reference only. in the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. errors and omissions excepted. thermal-magnetic circuit breakers 3600/3900 www.e-t-a.de 1646 1


▲Up To Search▲   

 
Price & Availability of 3900-P10-SI-01A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X